Input:
Powerlock overall proection via 400A 4P MCCB fitted with shunt trip operated by variable RCD with Disable
Unprotected 400A link through
Racklights front and black switchable blue/off/white
Digital multimeter
Output:
12 x Soca each channel protected by 16A 30mA 2P RCBO
indicators front and back
1 x 63A/3 protected by 3P MCB
1 x 32A/3 protected by 3P MCB
6 x 16A/1 each with RCBO
USB charger